Perform 5000 Suggested Use Link SOP

Perform 5000
Standard Operating Procedure (SOP)
Perform 5000 is compatible with all processing solvents.
Safety: Please adhere to the safety and handling
instructions in the Perform 5000 Safety Data Sheet (SDS), included with your shipment, available at
mediabros.store, or by emailing sales@mediabros.store.
Required Materials:
- Perform 5000 Filtration Media
-
In-line Filtration Housing & Filter
- CRC Column Size: For best results, use a 4–6 inch diameter column.
- Filter: Optimized for use with a ≤5-micron screen filter followed by a 0.2-micron, Media Bros Ulti-Filter.
Recommended Conditions:
Solvent-to-biomass ratio: 6:1 to 10:1
Operating temperature: Below -10°C, will not clog due to ice
Flow rate: < 1 GPM. A needle valve or flow restrictor at the column base
improves flow control.
Procedure:
-
Determine your ratio. For every pound of biomass, load 150–250 grams
of Perform 5000 into the filtration housing. The exact amount depends on biomass quality and desired
outcome. Refer to the quick reference table:
Perform 5000 (Media Use Based on Grade)
Plant Matter Low Grade Medium Grade High Grade 1 lb 250g 200g 150g 2 lbs 500g 400g 300g 5 lbs 1,250g 1,000g 750g 10 lbs 2,500g 2,000g 1,500g 15 lbs 3,750g 3,000g 2,250g 20 lbs 5,000g 4,000g 3,000g 25 lbs 6,250g 5,000g 3,750g 30 lbs 7,500g 6,000g 4,500g 50 lbs 12,500g 10,000g 7,500g 100 lbs 25,000g 20,000g 15,000g - Secure filter screen and media. Ensure the filter screen is safely installed. A cloth or paper filter may be combined with a screen or plate. Load media directly into the column on top of the filter screen.
- No pre-wetting required. Perform 5000 is designed to be used dry.
- Run extraction using a POLAR OR NON-POLAR SOLVENT. Any lost yield can be recovered by flushing the media with pure solvent.
- Disposal. Follow all SDS instructions for safe disposal.